Note: These files can also be found in /media/shareX/Settings_EEG/Resources on Website
on fishfish
Electronics
Making a cable
Mouse Atlases
Step-by-Step Guide to Making LFP recording devices
- Wrap wire around jig
- Place taped "frets" under wire.
- Cut 4 pieces of plastic that will serve as your LFP electrode holders (plastic is 0.5mm thick).
- Separate the wires on the jig so that they achieve the desired spacing for your target structures.
- Remember that the stereoscope is magnified 2X. Therefore, the measurements in the eyepiece micrometer is doubled (i.e. 1mm = 2mm).
- Be gentle. Make small, dragging movements. Alternate ends.
- Remember that the stereoscope is magnified 2X. Therefore, the measurements in the eyepiece micrometer is doubled (i.e. 1mm = 2mm).
- Place plastic pieces onto strings (on the inside of the fret). Then glue in place with super glue.
- Cut glass tube (electrode casing) to right above length required for target structure (6mm is safe).
- Neuralynx tubing.
- One tube per electrode (corticals don't require glass tube).
- Rule of thumb: less than 2.2mm deep, no glass required.
- Neuralynx tubing.
- Cut wires thrice. On each end near the peg (2X) and down the middle.
- The end result is a rough, working electrode manifold.
- watch video
- another video
- The end result is a rough, working electrode manifold.
- Cut small pieces of tape to hold electrodes.
- Place rough, working electrode down on surface, wire side up. Then tape longer wired end down so that shorter wired end pivots up.
- Slip glass tubes over each subcortical electrode - slide all the way down.
- Once in place, glue use super glue to fasten tubes to plastic piece. Let dry for a few minutes.
- watch video (not great until 1/2 way through)
- Once in place, glue use super glue to fasten tubes to plastic piece. Let dry for a few minutes.
- Cut electrode/tubes to desired length to achieve target depth.
- Remember 2X stereoscope magnification. Therefore, for example, if target depth is 5.5mm, then length under eyepiece micrometer should read 11mm.
- Remember 2X stereoscope magnification. Therefore, for example, if target depth is 5.5mm, then length under eyepiece micrometer should read 11mm.
- Cut A-M Systems, stainless steel wire about 2-2.5cm long and make lasso/hook at the end.
- This piece will serve as a holder.
- This piece will serve as a holder.
- Coat plastic manifold with 5 minute epoxy.
- Keep tape on wires so that you can hold it while coating plastic.
- You can dremel wooden end of cotton swap to make cone-shaped applicator.
- watch video
- Once coated (and before glue has hardened), tape manifold down, with LFP electrodes hanging over the side.
- Then place loop/lasso end of A-M Systems holder onto plastic part, with handle parallel to long wires.
- Let glue dry.
- Keep tape on wires so that you can hold it while coating plastic.
- Strip ends of non-LFP wires (~1mm). These ends will be soldered to the DigiKey manifold.
- Solder wire to appropriate ends of manifold.
- Clamp DigiKey manifold with hemostats. Using A-M Systems holder, twist wires 5-7 times and then situate plastic end in the middle of the DigiKey manifold.
- Once in place, use small strip of tape to hold down A-M Systems holder. Tape all around edge of DigiKey manifold - will have to remove hemostats. Once around, reclamp with hemostats and place electrode down for dental cementing.
- watch video
- Once in place, use small strip of tape to hold down A-M Systems holder. Tape all around edge of DigiKey manifold - will have to remove hemostats. Once around, reclamp with hemostats and place electrode down for dental cementing.
- Dental cement the whole shebang.
- Measure electrode resistance. Aiming for >30kOhms.
- Wrap wire around jig
Cutting wires
Original picture
Example of "Fill"

I'm cutting wires!
Example of Resize

I'm cutting wires!
Example of Fit with white background color

I'm cutting wires!
Example of Fit floating to the left

I'm cutting wires!
- Cut electrode/tubes to desired length to achieve target depth.
- Remember 2X stereoscope magnification. Therefore, for example, if target depth is 5.5mm, then length under eyepiece micrometer should read 11mm.
Example of Fit with white background color, no image borders

I'm cutting wires!
Example of Fit with white background color, no image borders, no captions